Back to Superior Service Web Site

 

GAS ANALYZER PRODUCTS

PDA4GBD - 4 GAS ANALYZER WITH DISPLAY

PDA5GBD - 5 GAS ANALYZER WITH DISPLAY

PDA4GBA - 4 GAS ANALYZER

PDA5GBD - 5 GAS ANALYZER  

 

 

The Omitec PDA4GBA / PDA4GBD and PDA5GBA / PDA5GBD Emission Benches are specifically designed for portable emission analysis. Their small size, low weight and 12v operation make them ideal for road testing vehicles or using among multiple repair bays.
PRODUCT KIT CONTENTS: PDA4GBA/PDA5GBA, 4 or 5 gas emissions analyzer, PDA4GBA/PDA5GBA software on PCMCIA card, serial communications cable (RJ-45 to DB-9), 12V battery adapter lead, hose kit, PDA4GBA/PDA5GBA user's manual, (2) replacement filters and A/C Adapter.
PRODUCT KIT CONTENTS: PDA4GBD/PDA5GBD, 4 or 5 gas emissions analyzer with modular display, PDA4GBA/PDA5GBA software on PCMCIA card, serial communications cable (RJ-45 to DB-9), 12V battery adapter lead, hose kit, PDA4GBD/PDA5GBD user's manual, (2) replacement filters and A/C Adapter.
 The PDA4GBA / PDA4GBD and PDA5GBA / PDA5GBD provide the following features:
  • Meets OIML R 99 Class 1 and ISO 3930, BAR 90 and BAR 97 accuracy requirements for repair grade equipment
  • Monitors all gasses (CO, CO2, O2, HC and NOX, AFR and Lambda)
  • Connects to the PDA family of hand-held analyzers for portable testing as well as to PC’s and laptops for in-shop or on the road testing (PDA4GBA/PDA5GBA)
  • Operates off the vehicle battery or A/C Adapter (provided)
  • Weighs less than 12 lb.

These benches are the latest in emissions analyzer design, providing hundreds of hours of reliable service. Field replacement of filters and sensors is quick and easy.

Additional hardware options and software modules are available for the PDA4GBA and PDA5GBA.

 

 PDA4GBA / PDA4GBD and PDA5GBA / PDA5GBD Emissions Analyzer Specifications 

System Features

  • Designed for portable on-the-road or stationary emissions testing
  • Completely portable automotive emissions diagnostics and enhanced emission testing
  • Meets OIML R 99 Class 1 and 0 and ISO 3930, BAR 90 and BAR 97 accuracy specifications
  • Live emission data through PDA100A, PDA2050A or PDA2050
  • Live emission data through PC or Laptop interface (optional feature)
  • PDA4GBD/PDA5GBD are equipped with display and keypad and are standalone (do not require additional handheld unit or PC)
  • Extremely lightweight and small in size
  • Switch between gas data and engine diagnostic features
  • Operates off vehicle battery while sitting in the vehicle trunk or seat
  • Used with the PDA family of hand-held analyzers that provide (PDA4GBA/PDA5GBA):
    • - Large screen displays up to 8 panels of data at a time
    • - Save screens as reports (up to 20)
    • - Display all gases, RPM, AFR, Lambda and one multimeter panel (all with min/max)

System Specifications

Display Specifications

  • HC: 0 to 9999 PPM (Hexane)
  • CO: 0 to 10%
  • CO2: 0 to 20%
  • O2: 0 to 21%
  • NOx: 0 to 4000 ppm (MPDA5GBA)

Accuracy

  • HC: (4 ppm)
  • CO: (0.02%)
  • CO2: (0.3%)
  • O2: (0.1%)
  • NOx:
    • 0 to 4,000 ppm (25 ppm)
    • 4,001 to 5,000 ppm (+- 5% rel.)
       

Response time

  • Time to measure 90% of full scale is 4 sec (T90 = 4 sec)

Resolution

  • HC: 1 ppm
  • CO: 0.001 vol. %
  • CO2: 0.01 vol. %
  • O2: 0.01 vol. %
  • NOx: 1 ppm

Flow rate:

  • 0.3 to 3.0 liters/min

Power Requirements

  • 12 VDC
  • 1 Amp typical, 3.5 Amps max
  • 12 Watts typical

Physical Dimensions

  • Length: 12" / 30 cm
  • Width: 11.5" / 29 cm
  • Height: 6" / 15 cm
  • Weight: less than 11 lb. / 5.32 Kg

 

Typical engine conditions detected from tailpipe readings
 HC CO CO2 O2 NOx Possible Cause
H L L H L Excessively lean condition
H L H H H Moderately lean condition
L L L H L Exhaust leak
H H L L L Rich mixture 
H H L H L Rich mixture with misfire
 

 

     
  • 4 Gas meter with RPM and auxiliary input measurement
  • Min/max keeps track of test data
  • Displays live engine emissions in the shop bay or on the road
  • Screens can be stored for uploading to PC or direct printing
  • 5 Gas running histograph with AFR, RPM and auxiliary input
  • Auto ranging for best display
  • Graphs scroll to left when filled
  • Can Record up to to 8 files of 30 minutes each for later replay
  • Replay of 5-Gas running histograph and meter files
  • Full cursor function with digital readouts
  • Continuous recording, no last data points
  • Performs on the road or in the bay
 

Superior Service  P. O. BOX 86023  Portland, OR 97286

Copyright © 2008 Superior Service and Equipment  All rights reserved.
Revised: -->03/01/2008